# Three-tier back deck — 32'-0" × 24'-0" overall, freestanding.
#
# Demonstrates SHARED POSTS between tiers: a post on a tier line carries
# the upper tier's beam near its top and the lower tier's beam partway
# down, so one 6x6 serves two levels. Look at P6, P12, P13 and P16 in
# the ISO — they run past one deck to reach the next.
#
# Tier 2 bears at 1'-5-3/4" and not a round 1'-8": its beam shares the y=10
# posts with T1-S, and at 1'-8" the two would have overlapped in elevation by
# 2-1/4". Two 3" beams cannot occupy the same wood in a 5-1/2" post. Dropped
# to 1'-5-3/4", T2-N's top lands exactly on T1-S's underside and P6, P7, P8
# and P11 carry two pockets stacked in one face. The step it costs is real
# and the FINDINGS panel prices it in risers.
#
# Elevations here are INPUTS ONLY — bottom-of-beam (bearing_ft) per tier:
#   Tier 1  bearing 2'-3"   (at the house)
#   Tier 2  bearing 1'-5-3/4"
#   Tier 3  bearing 0'-4"
#
# Tiers 1 and 2 are FLUSH framed (joists hung between the beams in
# hangers). Tier 3 is DROP framed (joists run over the top of its beams),
# so its deck sits a full joist depth above its beam tops and it takes
# hurricane ties instead of hangers — and its rims sit at joist level
# (top_ft), nailed to the joist ends rather than hung between the beams.
#
# Deck tops, post cut lengths and the step between tiers are all DERIVED
# from those bearings plus each member's section depth. Read them off the
# TAKEOFF and FINDINGS panels — never from a comment. Restating a derived
# number in prose is how a model and its output drift apart.

# 2by's libraries this design is checked against (docs/materials-plan.md):
# no revision, so a demo always follows 2by's current ones.
materials: { lumber: southern-pine, hardware: simpson }

project:
  slug: tiered-deck
  title: Three-Tier Back Deck
  revision: r3
  date: 2026-09-02
  live_psf: 40
  dead_psf: 10
  allowable_psf: 1500
  waste_pct: 10
  bearing_ft: 2'-3"

# No slab under a deck — every post gets its own pier, so all posts are
# marked perimeter: false and the foundation panel calls them all out.
slab:
  field_in: 0
  perimeter_in: 0
  perimeter_width_in: 0

phases:
  - id: p1
    name: Upper + Middle Tier
  - id: p2
    name: Lower Tier

# STOCK OVERRIDE, kept deliberately. Lengths normally live in the LUMBER file
# and every model reads them from there. This job is buying from a yard with a
# thinner rack — 2x8 in 8 and 12 only, 6x6 in 12 only — so it states its own
# and the tool reports each override in the Findings. It is also what makes
# this model's cut list interesting: a constrained rack is where nesting and
# offcut actually cost money.
stock:
  2x8: [8, 12]
  2x10: [10, 12, 16]
  6x6: [12]

posts:
  # --- house side, y = 0 (tier 1 north beam)
  - id: P1
    at: [0, 0]
    size: 6x6
    phase: p1
    perimeter: false
  - id: P2
    at: [8, 0]
    size: 6x6
    phase: p1
    perimeter: false
  - id: P3
    at: [16, 0]
    size: 6x6
    phase: p1
    perimeter: false
  - id: P4
    at: [24, 0]
    size: 6x6
    phase: p1
    perimeter: false
  - id: P5
    at: [32, 0]
    size: 6x6
    phase: p1
    perimeter: false

  # --- tier 1 / tier 2 line, y = 10'-0"  (SHARED POSTS, two elevations)
  - id: P6
    at: [0, 10]
    size: 6x6
    phase: p1
    perimeter: false
  - id: P7
    at: [8, 10]
    size: 6x6
    phase: p1
    perimeter: false
  - id: P8
    at: [16, 10]
    size: 6x6
    phase: p1
    perimeter: false
  - id: P9
    at: [24, 10]
    size: 6x6
    phase: p1
    perimeter: false
  - id: P10
    at: [32, 10]
    size: 6x6
    phase: p1
    perimeter: false
  - id: P11
    at: [20, 10]
    size: 6x6
    phase: p1
    perimeter: false

  # --- tier 2 / tier 3 line, y = 18'-0"  (SHARED POSTS, two elevations)
  - id: P12
    at: [0, 18]
    size: 6x6
    phase: p1
    perimeter: false
  - id: P16
    at: [6, 18]
    size: 6x6
    phase: p1
    perimeter: false
  - id: P13
    at: [12, 18]
    size: 6x6
    phase: p1
    perimeter: false
  - id: P14
    at: [20, 18]
    size: 6x6
    phase: p1
    perimeter: false

  # --- lower tier outer edge, y = 24'-0"
  - id: P17
    at: [0, 24]
    size: 6x6
    phase: p2
    perimeter: false
  - id: P18
    at: [6, 24]
    size: 6x6
    phase: p2
    perimeter: false
  - id: P19
    at: [12, 24]
    size: 6x6
    phase: p2
    perimeter: false

beams:
  # ---------------- TIER 1 · bearing 2'-3" ----------------
  - id: T1-N
    label: Tier 1 house beam
    axis: x
    supports: [P1, P2, P3, P4, P5]
    plies: 2
    section: 2x10
    trib_ft: 5
    bearing_ft: 2'-3"
    phase: p1
  - id: T1-S
    label: Tier 1 outer beam
    axis: x
    supports: [P6, P7, P8, P11, P9, P10]
    plies: 2
    section: 2x10
    trib_ft: 5
    bearing_ft: 2'-3"
    phase: p1
  - id: T1-RW
    label: Tier 1 west rim
    axis: y
    supports: [P1, P6]
    plies: 1
    section: 2x10
    trib_ft: 0
    bearing_ft: 2'-3"
    phase: p1
  - id: T1-RE
    label: Tier 1 east rim
    axis: y
    supports: [P5, P10]
    plies: 1
    section: 2x10
    trib_ft: 0
    bearing_ft: 2'-3"
    phase: p1

  # ---------------- TIER 2 · bearing 1'-8" ----------------
  - id: T2-N
    label: Tier 2 upper beam
    axis: x
    supports: [P6, P7, P8, P11]
    plies: 2
    section: 2x10
    trib_ft: 4
    bearing_ft: 1'-5-3/4"
    phase: p1
  - id: T2-S
    label: Tier 2 outer beam
    axis: x
    supports: [P12, P16, P13, P14]
    plies: 2
    section: 2x10
    trib_ft: 4
    bearing_ft: 1'-5-3/4"
    phase: p1
  - id: T2-RW
    label: Tier 2 west rim
    axis: y
    supports: [P6, P12]
    plies: 1
    section: 2x10
    trib_ft: 0
    bearing_ft: 1'-5-3/4"
    phase: p1
  - id: T2-RE
    label: Tier 2 east rim
    axis: y
    supports: [P11, P14]
    plies: 1
    section: 2x10
    trib_ft: 0
    bearing_ft: 1'-5-3/4"
    phase: p1

  # ---------------- TIER 3 · bearing 0'-4" ----------------
  - id: T3-N
    label: Tier 3 upper beam
    axis: x
    supports: [P12, P16, P13]
    plies: 2
    section: 2x8
    trib_ft: 3
    bearing_ft: 0'-4"
    phase: p2
  - id: T3-S
    label: Tier 3 outer beam
    axis: x
    supports: [P17, P18, P19]
    plies: 2
    section: 2x8
    trib_ft: 3
    bearing_ft: 0'-4"
    phase: p2
  - id: T3-RW
    label: Tier 3 west rim
    axis: y
    supports: [P12, P17]
    plies: 1
    section: 2x8
    trib_ft: 0
    top_ft: 1'-6-1/2"      # joist level, not beam level — T3 is drop framed
    phase: p2
  - id: T3-RE
    label: Tier 3 east rim
    axis: y
    supports: [P13, P19]
    plies: 1
    section: 2x8
    trib_ft: 0
    top_ft: 1'-6-1/2"      # joist level, not beam level — T3 is drop framed
    phase: p2

joist_fields:
  - id: T1
    label: Tier 1
    section: 2x10
    span_axis: y
    bounds_x: [0, 32]
    bounds_y: [0, 10]
    framing: flush
    spacing_in: 16
    bears_on: [T1-N, T1-S]
    blocking: true
    phase: p1
  - id: T2
    label: Tier 2
    section: 2x10
    span_axis: y
    bounds_x: [0, 20]
    bounds_y: [10, 18]
    framing: flush
    spacing_in: 16
    bears_on: [T2-N, T2-S]
    blocking: true
    phase: p1
  - id: T3
    label: Tier 3
    section: 2x8
    span_axis: y
    bounds_x: [0, 12]
    bounds_y: [18, 24]
    framing: drop           # joists run OVER these beams — deck sits a joist depth higher
    spacing_in: 16
    bears_on: [T3-N, T3-S]
    blocking: true
    phase: p2

connections:
  # ---- tier 1 notched bearings
  - at: P1
    member: T1-N
    type: notch
  - at: P2
    member: T1-N
    type: notch
  - at: P3
    member: T1-N
    type: notch
  - at: P4
    member: T1-N
    type: notch
  - at: P5
    member: T1-N
    type: notch
  - at: P6
    member: T1-S
    type: notch
  - at: P7
    member: T1-S
    type: notch
  - at: P8
    member: T1-S
    type: notch
  - at: P11
    member: T1-S
    type: notch
  - at: P9
    member: T1-S
    type: notch
  - at: P10
    member: T1-S
    type: notch

  # ---- tier 2 notched bearings (lower notch, same posts at y=10)
  - at: P12
    member: T2-S
    type: notch
  - at: P16
    member: T2-S
    type: notch
  - at: P13
    member: T2-S
    type: notch
  - at: P14
    member: T2-S
    type: notch

  # ---- tier 2 upper beam, stacked under T1-S on the same posts
  - at: P6
    member: T2-N
    type: notch
  - at: P7
    member: T2-N
    type: notch
  - at: P8
    member: T2-N
    type: notch
  - at: P11
    member: T2-N
    type: notch

  # ---- tier 3 notched bearings (lower notch, same posts at y=18)
  - at: P12
    member: T3-N
    type: notch
  - at: P16
    member: T3-N
    type: notch
  - at: P13
    member: T3-N
    type: notch
  - at: P17
    member: T3-S
    type: notch
  - at: P18
    member: T3-S
    type: notch
  - at: P19
    member: T3-S
    type: notch

  # ---- rims hung, never notched, so no post is ever cross-notched
  - at: P1
    member: T1-RW
    type: hung
    into: T1-N
    part: LU210
  - at: P6
    member: T1-RW
    type: hung
    into: T1-S
    part: LU210
  - at: P5
    member: T1-RE
    type: hung
    into: T1-N
    part: LU210
  - at: P10
    member: T1-RE
    type: hung
    into: T1-S
    part: LU210
  - at: P6
    member: T2-RW
    type: hung
    into: T2-N
    part: LU210
  - at: P12
    member: T2-RW
    type: hung
    into: T2-S
    part: LU210
  - at: P11
    member: T2-RE
    type: hung
    into: T2-N
    part: LU210
  - at: P14
    member: T2-RE
    type: hung
    into: T2-S
    part: LU210
  # T3's rims are drop-framed: they nail to the joist ENDS at joist level,
  # so they take no hanger. Only the flush tiers above use LU210/LU28.